|本期目录/Table of Contents|

[1]陈华荣,庄 莉,陆文君,等.敏感指标在消毒供应中心医疗器械灭菌质量管控中的作用[J].传染病信息,2019,05:431-433.
 CHEN Hua-rong*,ZHUANG Li,LU Wen-jun,et al.Significance of sensitive index tosterilization quality control of medical devices in disinfection supply center[J].Infectious Disease Information,2019,05:431-433.
点击复制

敏感指标在消毒供应中心医疗器械灭菌质量管控中的作用(PDF)

《传染病信息》[ISSN:1007-8134/CN:11-3886/R]

期数:
2019年05期
页码:
431-433
栏目:
论著
出版日期:
2019-11-13

文章信息/Info

Title:
Significance of sensitive index tosterilization quality control of medical devices in disinfection supply center
文章编号:
1007-8134(2019)05-0431-03
作者:
陈华荣庄 莉陆文君陈 新
 210012,南京医科大学附属南京医院(南京市第一医院)
Author(s):
CHEN Hua-rong* ZHUANG Li LU Wen-jun CHEN Xin
Disinfection Supply Center, Nanjing Hospital Affiliated to Nanjing Medical University (Nanjing No. 1 Hospital), 210012, China
关键词:
消毒供应中心灭菌质量敏感指标
Keywords:
disinfection supply center sterilization quality sensitive indicators
分类号:
R197.323
DOI:
10.3969/j.issn.1007-8134.2019.05.013
文献标识码:
A
摘要:
目的探究消毒供应中心按照敏感指标要求进行质量控制对医疗器械灭菌质量管控的意义。方法将南京医科大学附属南京医院(南京市第一医院)消毒供应中心 2017年 1—12月间处理的医疗器械随机抽取 500件作为对照组,此期间采用常规质量管理方法对医疗器械的清洗、灭菌质量进行控制;将 2018年 1—12月间处理的医疗器械随机抽取 500件作为研究组,此期间按照敏感指标的要求对医疗器械的清洗、灭菌质量进行控制。应用 SPSS软件,对 2组间的清洗质量合格率、湿包发生率、包装质量合格率进行比较。结果对照组的清洗、包装合格率分别为 87.8%(439/500)、89.2%(446/500),研究组的清洗、包装合格率均为 95.0%(475/500)。与对照组相比,研究组的清洗、包装合格率均明显提高( P均< 0.05)。研究组的湿包发生率为 1.0%明显低于对照组的 8.0%(P< 0.05)。结论消毒供应中心按照敏感指标的要求对医疗器械灭菌质量进行管控,可有效提高医疗器械清洗消毒质量和包装质量的合格率,是实现医疗器械灭菌质量的重要保障,对降低院内感染,保证患者安全有重要意义。
Abstract:
ObjectiveTo explore the significance of quality control by using sensitive indexes in disinfection supply centerto control the sterilization quality of medical devices. MethodsMedical devices handled by the disinfection supply room of NanjingHospital affiliated to Nanjing Medical University (Nanjing No. 1 Hospital) from January to December in 2017 were taken as the control group, and the conventional quality management method was used to control the cleaning and sterilization quality of medical devices;medical devices handled by the disinfection supply room of Nanjing Hospital affiliated to Nanjing Medical University (Nanjing No. 1Hospital) from January to December in 2018 were taken as the study group, and sensitive indicators were used to control the quality of cleaning and sterilization of medical devices. Using SPSS software, the qualification rate of cleaning quality, the incidence of wet packets and the qualification rate of packaging quality were compared between 2 groups. ResultsThe pass rates of cleaning and packing inthe control group were 87.8% (439/500) and 89.2% (446/500) respectively, and those in the study group were both 95.0% (475/500).Compared with the control group, the pass rate of cleaning and packing in the study group was obviously improved (P< 0.05). The incidence of wet packets in the study group (1.0%) was significantly lower than that in the control group (8.0%) (P< 0.05). ConclusionsThe application of sensitive indexes in disinfection supply room to control the sterilization quality of medical devices can effectively improve the pass rate of medical device cleaning and disinfection quality and packaging quality. It is an important guarantee to realize the quality of medical device sterilization, and is of great significance for reducing nosocomial infection and ensuring patient safety.

参考文献/References

[1] 曾小娟 . 消毒供应室医疗器械的清洗与质量检测[J]. 医疗装备,2018,31(3):67-68.
[2] 俞慧,赵海燕 . 消毒供应室质量管理对手术室器械清洗包装的影响观察[J]. 世界最新医学信息文摘,2018,18(65):231?232.
[3] 季玲,林素英 . 外来医疗器械清洗效果质量敏感指标的设定与效果评价[J]. 上海护理,2018,18(12):79-82.
[4] 黄恒慧 . 质量敏感指标在消毒供应室外来医疗器械质量管理中的应用研究[J]. 中国卫生产业,2018,15(3):156-158.
[5] 中华人民共和国卫生部 . 中华人民共和国卫生行业标准[J]. 中华医院感染学杂志,2009,19(16):2064-2066.
[6] 王晓莉,王玉霞,夏燕,等 . 护理敏感质量基础指标在病房护理质量管理中的应用[J]. 实用临床护理学电子杂志, 2017,2(47):193,196.
[7] 吴春玲,陈兰珍 . 质量敏感指标在消毒供应室骨科外来医疗器械质量管理中的应用[J]. 全科护理,2017,15(24):3037?3039.
[8] 马丽,吴红梅,王翠兰,等 . 应用护理质量敏感性指标监测腔镜器械清洗效果[J]. 中西医结合护理(中英文), 2018,4(4):46-48.
[9] 杜传荣 . 医院消毒供应室医疗器械的清洗质量控制管理[J]. 中国医疗器械信息,2017,23(15):147-148.
[10] 周园 . 影响消毒供应室再生医疗器械清洗质量的原因与对策[J]. 世界最新医学信息文摘,2018,18(54):219,222.
[11] 周敏,张艳,吴琼凤,等 . 消毒供应室的质量管理对控制医院感染的重要性[J]. 中国继续医学教育,2018,10(6):24?26.
[12] 余超超 . 强化质量控制管理在消毒供应中心器械消毒灭菌中的应用效果[J]. 医疗装备,2018,31(17):107-108.
[13] 陈莉莉 . 护理敏感性质量指标的研究现状[J]. 继续医学教育, 2018,32(5):104-106.

备注/Memo

备注/Memo:
[作者单位]210012,南京医科大学附属南京医院(南京市第一 医院)消毒供应中心(陈华荣、庄莉、陆文君、陈新)
[通信作者]陈华荣,E-mail:gdyym0429@163.com
*Correspondingauthor,E-mail:gdyym0429@163.com